WiFiScope WS6 WiFi oscilloscope
WiFiScope WS6 WiFi oscilloscope
WiFiScope WS6 WiFi oscilloscope
WiFiScope WS6 WiFi oscilloscope
WiFiScope WS6 WiFi oscilloscope
WiFiScope WS6 WiFi oscilloscope
WiFiScope WS6 WiFi oscilloscope
  • Load image into Gallery viewer, WiFiScope WS6 WiFi oscilloscope
  • Load image into Gallery viewer, WiFiScope WS6 WiFi oscilloscope
  • Load image into Gallery viewer, WiFiScope WS6 WiFi oscilloscope
  • Load image into Gallery viewer, WiFiScope WS6 WiFi oscilloscope
  • Load image into Gallery viewer, WiFiScope WS6 WiFi oscilloscope
  • Load image into Gallery viewer, WiFiScope WS6 WiFi oscilloscope
  • Load image into Gallery viewer, WiFiScope WS6 WiFi oscilloscope

WiFiScope WS6 WiFi oscilloscope

Regular price
$3,010.00
Sale price
$3,010.00
Regular price
Sold out
Unit price
per 

Key specifications

  • 8, 12, 14, 16 bit resolution, 0.25 % DC vertical accuracy, 0.1 % typical
  • Up to 1 GSa/s sampling, up to 250 MHz bandwidth
  • Up to 256 MSamples memory per channel
  • Up to 200 MSs/s continuous streaming
  • 1 ppm time base accuracy

This powerful high speed WiFi oscilloscope combines fast sampling up to 1 GSa/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 MSamples on all four channels. The oscilloscope supports continuous streaming measurements up to 200 MSa/s and can be synchronized with other oscilloscopes using the CMI interface to form a multi channel combined instrument with synchronized time base. The CMI interface is available by default on the WiFiScope WS6. Optionally, the WiFiScope WS6 can be delivered with SureConnect connection test and resistance measurement on each channel.

The flexibility and quality that the WiFiScope WS6 offers is unparalleled by any other oscilloscope in its class.

Rugged industrial design

The WiFiScope WS6 features a rugged design. Its enclosure is fitted with rubber protectors at the front and the rear. These protect the WiFiScope WS6 against damage by mechanical shocks. The rubber helps absorbing shocks and protects the connectors at the front and the rear of the WiFiScope WS6, these fall within the protected zone.

Additionally, the rubber prevents your WiFiScope WS6 from sliding. The rubber protectors have special notches that simplify stacking instruments. Holes are included that allow to connect a strap to hang the instrument near the test subject.

SureConnect

The SureConnect connection test feature of the WiFiScope WS6 tells you immediately whether your test probe or clip actually makes electrical contact or not. No more doubt whether your probe doesn't make contact or there really is no signal.

EMI pre compliance testing

The powerful capabilities of the WiFiScope WS6 - 1000XMES EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.

Multi instrument synchronisation

The WiFiScope WS6 is equipped with a sophisticated CMI synchronization bus, allowing to connect multiple WiFiScope WS6s to each other by means of TP-C50H Coupling cable CMIs, to use them as a combined instrument. All instruments will measure at the same sample frequency (0 ppm deviation!). Apart from a synchronization bus, the CMI also contains a trigger bus and a detection bus. The maximum number of instruments is only limited by the number available USB ports.

High accuracy

The WiFiScope WS6 measures with high resolutions of 14 and 16 bit. A signal measured with the WiFiScope WS6 therefore has 256 times more resolution than most standalone oscilloscopes, which usually have a low resolution of 8 or 9 bit. The high resolution of the WiFiScope WS6 precision oscilloscope allows for measuring signals with more accuracy, because the quantization error is much lower.

Large memory

When measuring at high sample rates, a long record length/large memory is necessary to be able to record a complete signal in the acquisition buffer. Where most oscilloscopes have 2.5 kSamples or 100 kSamples memory, the WiFiScope WS6 has up to 256 MSamples memory per channel, depending on the selected resolution and the number of active channels. When measuring at 14 bit resolution and all four channels, the available memory is 32 MSamples per channel. This gives the user 300 to 100000 times more memory. An advantage of a large memory is that once-only fast phenomena can be captured accurately or complete serial communication signal blocks can be measured all at once. For example complete serial communications, like CAN bus signals, can be measured all in one record to be reviewed and analyzed afterwards.

Bandwidth limit

It seems reasonable to assume that more bandwidth is better, but a wider bandwidth gives more noise. To reduce your noise you can switch on a bandwidth limiter for each channel of the WiFiScope WS6.

Acquisition system

Number of input channels 4 analog
CH1, CH2, CH3, CH4 Female BNC
Type Single ended input
Resolution 8, 12, 14, 16 bit user selectable
DC Accuracy 0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C
To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize.
Ranges (full scale) ±200 mV
±400 mV
±800 mV
±2 V
±4 V
±8 V
±20 V
±40 V
±80 V
Coupling AC/DC
Impedance 1 MΩ / 20 pF ± 1 %
Maximum voltage 200 V (DC + AC peak < 10 kHz)
Bandwidth WS6-1000 WS6-500 WS6-200
-3dB at 75 % of full scale input 250 MHz 250 MHz 250 MHz
Limit, selectable per channel Off (250 MHz)
150 MHz
100 MHz
50 MHz
Off (250 MHz)
150 MHz
100 MHz
50 MHz
Off (250 MHz)
150 MHz
100 MHz
50 MHz
AC coupling cut off frequency (-3dB) ±1.5 Hz
SureConnect Optionally available (option S)
Maximum voltage on connection 200 V (DC + AC peak < 10 kHz)
Resistance measurement Optionally available (option S)
Ranges (Full scale) 1 kΩ
2 kΩ
5 kΩ
10 kΩ
20 kΩ
50 kΩ
100 kΩ
200 kΩ
500 kΩ
1 MΩ
2 MΩ
Accuracy 1 % of full scale
Response time (to 95%) < 10 µs
 
Maximum sampling rate WS6-1000 WS6-500 WS6-200
8 bit  
measuring one channel 1 GSa/s 500 MSa/s 200 MSa/s
measuring two channels 500 MSa/s 200 MSa/s 100 MSa/s
measuring three or four channels 200 MSa/s 100 MSa/s 50 MSa/s
12 bit  
measuring one channel 500 MSa/s 200 MSa/s 100 MSa/s
measuring two channels 200 MSa/s 100 MSa/s 50 MSa/s
measuring three or four channels 100 MSa/s 50 MSa/s 20 MSa/s
14 bit 100 MSa/s 50 MSa/s 20 MSa/s
16 bit 6.25 MSa/s 3.125 MSa/s 1.25 MSa/s
 
Maximum streaming rate 1 WS6-1000 WS6-500 WS6-200
8 bit  
measuring one channel 200 MSa/s 2 100 MSa/s 2 40 MSa/s
measuring two channels 100 MSa/s 3 50 MSa/s 3 20 MSa/s
measuring three or four channels 50 MSa/s 4 25 MSa/s 4 10 MSa/s
12 bit  
measuring one channel 100 MSa/s 3 50 MSa/s 3 20 MSa/s
measuring two channels 50 MSa/s 4 25 MSa/s 4 10 MSa/s
measuring three or four channels 25 MSa/s 5 12.5 MSa/s 5 5 MSa/s
14 bit  
measuring one channel 100 MSa/s 3 50 MSa/s 3 20 MSa/s
measuring two channels 50 MSa/s 4 25 MSa/s 4 10 MSa/s
measuring three or four channels 25 MSa/s 5 12.5 MSa/s 5 5 MSa/s
16 bit 6.25 MSa/s 6 3.125 MSa/s 1.25 MSa/s
  1. Due to computer restrictions, on some computers the highest streaming rates may not be available.
    When LAN/WiFi connected, the maximum streaming rate is limited, and depends on the quality of the network.
  2. ≤ 40 MSs/s when connected to USB 2.0 or via LAN/WiFi
  3. ≤ 20 MSs/s when connected to USB 2.0 or via LAN/WiFi
  4. ≤ 10 MSs/s when connected to USB 2.0 or via LAN/WiFi
  5. ≤ 5 MSs/s when connected to USB 2.0 or via LAN/WiFi
  6. ≤ 3.125 MSs/s when connected to USB 2.0 or via LAN/WiFi
Sampling clock source  
Internal TCXO
Accuracy ± 0.0001 %
Stability ± 1 ppm over 0°C to 55°C
Time base aging ±1 ppm/year
External LVDS, on CMI connectors
Input frequency 10 MHz ± 1 %
16.369 MHz ± 1 %
 
Memory Standard model XM option via USB XM option via WiFi/LAN
8 bit resolution  
Measuring one channel 1 MSa per channel 256 MSa per channel 64 MSa per channel
Measuring two channels 512 KSa per channel 128 MSa per channel 32 MSa per channel
Measuring three or four channels 256 KSa per channel 64 MSa per channel 16 MSa per channel
12, 14, 16 bit resolution  
Measuring one channel 512 KSa per channel 128 MSa per channel 32 MSa per channel
Measuring two channels 256 KSa per channel 64 MSa per channel 16 MSa per channel
Measuring three or four channels 128 KSa per channel 32 MSa per channel 8 MSa per channel
 
Trigger  
System Digital, 2 levels
Source CH1, CH2, CH3, CH4, OR, digital external
Trigger modes Rising edge, falling edge, any edge, inside window, outside window, enter window, exit window, pulse width
Level adjustment 0 to 100 % of full scale
Hysteresis adjustment 0 to 100 % of full scale
Resolution 0.006 % (14, 16 bits) / 0.025% (12 bits)
Pre trigger 0 to selected record length, 1 sample resolution
Post trigger 0 to selected record length, 1 sample resolution
Trigger hold-off 0 to 63 MSamples, 1 sample resolution
Trigger delay 0 to 8 GSamples, 1 sample resolution
Digital external trigger  
Input Extension connector pins 1 and 2
Range 0 to 2.5 V (TTL)
Coupling DC
Jitter ≤ 1 sample

Multi-instrument synchronization

Combining instruments is only available when all instruments are connected via USB.
When instruments are connected via LAN or WiFi, combining is not available.
Maximum number of instruments Limited by number of available USB ports
Synchronization accuracy 0 ppm
CMI interface 2x, CMI 1, CMI 2
Required coupling cable TP-C50H Coupling cable CMI
Maximum coupling cable length 50 cm

Probe calibration

Output Extension connector pins 3 (signal) and 6 (ground)
Signal Square wave
Level -1 V to 1 V
Frequency 1 kHz

Interface

Interface  
USB USB 3.0 SuperSpeed (5 Gbit/s);
(USB 2.0 HighSpeed compatible)
Network
LAN 1 Gbps
WiFi 802.11
Network port (TCPIP and UDP) 5450 (IANA assigned)

Power Requirements

Power From USB, external input or built-in battery
Consumption 12 VDC 2 A max
External power From power adapter
Internal battery Li-ion
Capacity 7000 mAh, 3.7 V

Physical

Instrument
Height 44 mm (1.7 inch)
Length 187 mm (6.7 inch)
Width 215 mm (5.2 inch)
Weight 791 g (27.9 ounce)
USB cord length 1.5 m (59 inch)

I/O connectors

Channel 1, 2, 3, 4 BNC
LAN RJ45 socket
USB USB 3.0 type B Super Speed socket
Extension connector D-sub 9 pins female
Power 3.5 mm power socket
CMI connectors 2 x HDMI type C socket

System requirements

PC I/O connection USB 2.0, USB 3.0 or USB 3.1
RJ45
WiFi
Operating system Windows 10, 32 and 64 bits
Linux (via own software using the LibTiePie SDK)

Environmental conditions

Operating  
Ambient temperature 20°C to 25°C for rated accuracy (10°C to 40°C without specifications)
Relative humidity 10 % to 90 %, non condensing
Charging  
Ambient temperature 0°C to 35°C
Relative humidity 10 % to 90 %, non condensing
Storage  
Ambient temperature 0°C to 35°C
Relative humidity 5 % to 95 %, non condensing

Certifications and Compliances

CE mark compliance Yes
RoHS Yes
EN 55011:2009/A1:2010 Yes
EN 55022:2006/A1:2007 Yes
EN 61000-6-1:2007 Yes
EN 61000-6-3:2007 Yes

Package contents

Instrument WiFiScope WS6
Probes 4 x Oscilloscope Probe 1:1-1:10 - HP-3250I
Accessories Handyscope / WiFiScope power supply
USB3 cable, 1.5 m long
network cable, 3 m long
Software for Windows 10, via website
Drivers for Windows 10, via website
Software Development Kit for Windows 10 and Linux, via website
Manuals instrument manual and software user's manuals
color printed and digital, via website

Optional Accessories

Optional accessories for the WiFiScope WS6 need to be ordered separately

Customer service

TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years.
This warranty includes All parts and labor (excluding probes and/or measure leads and/or batteries)
Warranty on batteries is 6 months.
No charge for return shipping
Long-term 7 year support
Upgrade to the latest software at no charge
Optionally available Extension to five year warranty, option W5