Key specifications

Acquisition system
  • 8, 12, 14, 16 bit resolution, 0.25 % DC vertical accuracy, 0.1 % typical
  • Up to 500 MSa/s sampling, up to 250 MHz bandwidth
  • Up to 32 MSamples memory per channel
  • 20 MSa/s, 14 bit continuous streaming
  • 1 ppm time base accuracy
Arbitrary Waveform Generator
  • 1 µHz up to 40 MHz sine, square, triangular, pulse and arbitrary waveforms
  • -12 to 12 V output (24 Vpp)
  • Up to 64 MSamples, 240 MSa/s, 14 bit arbitrary waveforms
  • Spurious (non harmonic) < -85 dB
  • 8 ns rise and fall time

This powerful high speed WiFi oscilloscope combines fast sampling up to 500 MSa/s with high resolutions of 12, 14 and 16 bit, a large memory of 64 MSamples and an extremely accurate built-in 40 MHz 14 bit Constant Data Size (CDS) arbitrary waveform generator with 24 V peak to peak output, generating true form signals. The oscilloscope supports continuous streaming measurements up to 20 MSa/s and can be synchronized with other oscilloscopes using the CMI interface to form a multi channel combined instrument with synchronized time base. The CMI interface is available by default on the WiFiScope WS5. Optionally, the WiFiScope WS5 can be delivered with SureConnect connection test and resistance measurement on each channel.

The flexibility and quality that the WiFiScope WS5 offers is unparalleled by any other oscilloscope and function generator in its class.

Rugged industrial design

The WiFiScope WS5 features a rugged design. Its enclosure is fitted with rubber protectors at the front and the rear. These protect the WiFiScope WS5 against damage by mechanical shocks. The rubber helps absorbing shocks and protects the connectors at the front and the rear of the WiFiScope WS5, these fall within the protected zone.

Additionally, the rubber prevents your WiFiScope WS5 from sliding. The rubber protectors have special notches that simplify stacking instruments. Holes are included that allow to connect a strap to hang the instrument near the test subject.

SureConnect

The SureConnect connection test feature of the WiFiScope WS5 tells you immediately whether your test probe or clip actually makes electrical contact or not. No more doubt whether your probe doesn't make contact or there really is no signal.

Multi instrument synchronisation

The WiFiScope WS5 is equipped with a sophisticated CMI synchronization bus, allowing to connect multiple WiFiScope WS5s to each other by means of TP-C50H Coupling cable CMIs, to use them as a combined instrument. All instruments will measure at the same sample frequency (0 ppm deviation!). Apart from a synchronization bus, the CMI also contains a trigger bus and a detection bus. The maximum number of instruments is only limited by the number available USB ports.

High accuracy

The WiFiScope WS5 measures with high resolutions of 14 and 16 bit. A signal measured with the WiFiScope WS5 therefore has 256 times more resolution than most standalone oscilloscopes, which usually have a low resolution of 8 or 9 bit. The high resolution of the WiFiScope WS5 precision oscilloscope allows for measuring signals with more accuracy, because the quantization error is much lower.

Large memory

When measuring at high sample rates, a long record length/large memory is necessary to be able to record a complete signal in the acquisition buffer. Where most oscilloscopes have 2.5 kSamples or 100 kSamples memory, the WiFiScope WS5 has 32 MSamples memory per channel. This gives the user 300 to 10000 times more memory. An advantage of a large memory is that once-only fast phenomena can be captured completely. For example complete serial communications, like CAN bus signals, can be measured all in one record to be reviewed and analyzed afterwards.

Low distortion Arbitrary Waveform Generator

The WiFiScope WS5 is the first High Resolution WiFi oscilloscope with built-in 30 MHz low distortion function generator. The built-in Arbitrary Waveform Generator uses CDS signal synthesis technology, developed by TiePie engineering, resulting in the best signal fidelity in its class, generating the true form of your signals. With spurious distortion as low as -85 dB at 100 kHz signal frequency, a very flat amplitude spectrum and a rise time of 8 ns, the low distortion function generator creates signals that approach perfection.

Oscilloscope and Generator synchronization

The High Resolution WiFi oscilloscope and the arbitrary waveform generator in the WiFiScope WS5 can be easily synchronized by setting the trigger source of the oscilloscope to one or more generator trigger events: start, stop and new period.

Acquisition system

Number of input channels 2 analog
CH1, CH2 BNC
Type Single ended
Resolution 8, 12, 14, 16 bit user selectable
DC Accuracy 0.25 % (0.1 % typical) of full scale ± 1 LSB
Ranges (Full scale) ±200 mV
±2 V
±20 V
±400 m
±4 V
±40 V
±800 mV
±8 V
±80 V
Coupling AC/DC
Impedance 1 MΩ / 25 pF ± 1 %
Maximum voltage 200 V (DC + AC peak < 10 kHz)
Maximum voltage 1:10 probe 600 V (DC + AC peak < 10 kHz)
Bandwidth (-3dB) at 75 % of full scale input
Ch1 250 MHz
Ch2 100 MHz
AC coupling cut off frequency (-3dB) ±1.5 Hz
SureConnect Optionally available (option S)
Maximum voltage on connection 200 V (DC + AC peak < 10 kHz)
Resistance measurement Optionally available (option S)
Ranges (Full scale) 100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
500 Ω
5 kΩ
50 kΩ
500 kΩ
Accuracy 1 % of full scale
Response time (to 95%) < 10 µs
Maximum sampling rate WS5-540 WS5-530 WS5-220
8/12 bit, measuring one channel 500 MSa/s 500 MSa/s 200 MSa/s
8/12 bit, measuring two channels 200 MSa/s 200 MSa/s 100 MSa/s
14 bit 100 MSa/s 100 MSa/s 50 MSa/s
16 bit 6.25 MSa/s 6.25 MSa/s 3.125 MSa/s
Maximum streaming rate 1 2 WS5-540 WS5-530 WS5-220
8 bit, measuring one channel 40 MSa/s 40 MSa/s 20 MSa/s
8 bit, measuring two channels 20 MSa/s 20 MSa/s 10 MSa/s
12/14 bit, measuring one channel 20 MSa/s 20 MSa/s 10 MSa/s
12/14 bit, measuring two channels 10 MSa/s 10 MSa/s 5 MSa/s
16 bit 6.25 MSa/s 6.25 MSa/s 3.125 MSa/s
  1. On some computers, the highest streaming rates may not be available, due to computer restrictions.
  2. When connected through WiFi, the maximum streaming rate is limited, and depends on the quality of the WiFi network.
Memory Standard model XM option
Measuring one channel 256 KSamples per channel 64 MSamples per channel
Measuring two channels 128 KSamples per channel 32 MSamples per channel
Sampling clock source  
Internal TCXO
Accuracy ± 0.0001 %
Stability ± 1 ppm over 0°C to 55°C
Time base aging ±1 ppm/year
External LVDS, on auxiliary connectors
Input frequency 10 MHz ± 1 %
16.369 MHz ± 1 %
Trigger  
System Digital, 2 levels
Source CH1, CH2, OR, digital external, generator start, generator new period, generator stop
Trigger modes Rising edge, falling edge, any edge, inside window, outside window, enter window, exit window, pulse width
Level adjustment 0 to 100 % of full scale
Hysteresis adjustment 0 to 100 % of full scale
Resolution 0.006 % (14, 16 bits) / 0.025% (12 bits)
Pre trigger 0 to selected record length, 1 sample resolution
Post trigger 0 to selected record length, 1 sample resolution
Trigger hold-off 0 to 63 MSamples, 1 sample resolution
Trigger delay 0 to 16 GSamples, 1 sample resolution
Segmented trigger Available on models with extended memory option XM, available via LibTiePie SDK
Maximum number of segments 1024
Minimum segment length 1 sample
Maximum segment length 32 M / number of segments
64 M / number of segments measuring one channel
Trigger rearm time Sample frequency dependent, < 700 ns on highest sample frequency
Digital external trigger  
Input Extension connector pins 1, 2 and 3
Range 0 to 2.5 V (TTL)
Coupling DC
Jitter Depending on source and sample frequency
Source = channel ≤ 1 sample
Source = external or generator  
Sample frequency = 500 MSa/s ≤ 8 samples
Sample frequency < 500 MSa/s ≤ 4 samples
Sample frequency ≤ 100 MSa/s ≤ 1 sample

Arbitrary Waveform Generator (independent from acquisition system)

Waveforms  
Standard Sine, square, triangle, pulse, noise, DC
Signal characteristics  
Sine WS5-540 WS5-530 WS5-220
Frequency range 1 µHz to 40 MHz 1 µHz to 30 MHz 1 µHz to 20 MHz
Amplitude flatness Relative to 1 kHz
< 100 kHz ±0.1 dB
< 5 MHz ±0.15 dB
< 20 MHz ±0.3 dB (Amplitude ≤ 11 V (22 Vpp))
< 30 MHz ±0.4 dB (Amplitude ≤ 9 V (18 Vpp))
< 40 MHz ±1 dB (Amplitude ≤ 7.5 V (15 Vpp))
Spurious (non harmonic)  
< 100 kHz -75 dBc
100 kHz to 1 MHz -70 dBc
1 MHz to 10 MHz -60 dBc
10 MHz to 15 MHz -55 dBc
15 MHz to 20 MHz -45 dBc
20 MHz to 30 MHz -35 dBc
30 MHz to 40 MHz -30 dBc
Square WS5-540 WS5-530 WS5-220
Frequency range 1 µHz to 30 MHz 1 1 µHz to 30 MHz 1 µHz to 20 MHz
Rise/fall time < 8 ns
Overshoot < 1 %
Variable duty cycle 0.01 % to 99.99 %
Asymmetry 0 % of period + 5 ns (@ 50 % Duty cycle)
Jitter (RMS) < 50 ps
Triangle WS5-540 WS5-530 WS5-220
Frequency range 1 µHz to 30 MHz 1 1 µHz to 30 MHz 1 µHz to 20 MHz
Nonlinearity (of peak output) < 0.01 %
Symmetry 0 % - 100 %, 0.1 % steps
Pulse  
Period 100 ns to 1000 s
Pulse width 15 ns to 1000 s
Variable edge time 8 ns to 1 s
Overshoot < 1 %
Jitter (rms) < 50 ps
Noise  
Bandwidth (typical) 30 MHz
Arbitrary WS5-540 WS5-530 WS5-220
Frequency range 0.4 nHz to 30 MHz 0.4 nHz to 30 MHz 0.4 nHz to 20 MHz
Maximum sample rate 240 MSa/s 240 MSa/s 200 MSa/s
Length  
Standard model 1 to 256 KiSamples
XM option 1 to 64 MiSamples
Rise/Fall time < 8 ns
Nonlinearity (of peak output) < 0.01 %
Settling time < 8 ns to 10 % final value
Jitter (RMS) < 50 ps
  1. Above 30 MHz not gespecified.
Common characteristics  
Number of output channels 1 analog, BNC
DAC resolution 14 bit
Output range At open circuit
frequency ≤ 10 MHz -12 to +12 V (24 Vpp)
frequency ≤ 20 MHz -11 to +11 V (22 Vpp)
frequency ≤ 30 MHz -9 to +9 V (18 Vpp)
frequency ≤ 40 MHz -7.5 to +7.5 V (15 Vpp)
Amplitude  
Ranges (at open circuit) 0.12 V (0.24 Vpp)
1.2 V (2.4 Vpp)
12 V (24 Vpp)
Resolution 12 bit
Accuracy 0.4 % of range
DC offset  
Range -12 to +12 V at open circuit
Resolution 12 bit
Accuracy 0.4 % of range
Noise level  
0.12 V range 900 µVRMS
1.2 V range 1.3 mVRMS
12 V range 1.5 mVRMS
Coupling DC
Impedance 50 Ω
Overload protection Output turns off automatically when overload is applied. Instrument will tolerate a short circuit to ground indefinitely.
Burst  
Waveforms Sine, square, triangle, noise, arbitrary
Count 1 to 65535
Trigger Software, external
Sweep Available on models with extended memory option XM
Waveforms Sine, square, triangle
Type Linear, logarithmic
Direction Up, down
Trigger Software, external
System characteristics  
System Constant Data Size
Memory  
Standard model 256 KiSamples
Option XM 64 MiSamples
Operating modes Continuous, triggered, gated
Maximum sample rate WS5-540 WS5-530 WS5-220
  240 MSa/s 240 MSa/s 200 MSa/s
Sampling source Internal TCXO
Accuracy ±0.0001 %
Stability ±1 ppm over 0°C to +55°C
Time base aging ±1 ppm/year

Multi-instrument synchronization

Combining instruments is only available when all instruments are connected via USB.
When instruments are connected via LAN or WiFi, combining is not available.
Maximum number of instruments Limited by number of available USB ports
Synchronization accuracy 0 ppm
CMI interface 2x, CMI 1, CMI 2
Required coupling cable TP-C50H Coupling cable CMI
Maximum coupling cable length 50 cm

Interface

Interface  
USB USB 2.0 High Speed (480 Mbit/s);
(USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible)
Network
LAN 1 Gbps
WiFi 802.11
Network port (TCPIP and UDP) 5450 (IANA assigned)

Power Requirements

Power From USB, external input or built-in battery
Consumption 12 VDC 2 A max
External power From power adapter
Internal battery Li-ion
Capacity 7000 mAh, 3.7 V

Physical

Instrument  
Height 44 mm (1,7 inch)
Length 187 mm (7.4 inch)
Width 215 mm (8.5 inch)
Weight 751 g (26.5 ounce)
USB cord length 1.5 m (59 inch)

I/O connectors

Channel 1, 2 BNC
AWG BNC
USB USB 3 type B Super Speed socket
LAN RJ45 socket
Extension connector D-sub 9 pins female
Power 3.5 mm power socket
CMI connectors 2 x HDMI type C socket

System requirements

PC I/O connection USB 1.1, USB 2.0 or newer
RJ45
WiFi
Operating system Windows 10, 32 and 64 bits
Linux (via own developed software using the LibTiePie SDK)

Environmental conditions

Operating  
Ambient temperature 15°C to 35°C within rated accuracy (10°C to 40°C without specifications)
Relative humidity 10 % to 90 %, non condensing
Charging  
Ambient temperature 0°C to 35°C
Relative humidity 10 % to 90 %, non condensing
Storage  
Ambient temperature 0°C to 35°C
Relative humidity 5 % to 95 %, non condensing

Certifications and Compliances

CE mark compliance Yes
RoHS Yes
EN 55011:2009/A1:2010 Yes
EN 55022:2006/A1:2007 Yes
EN 61000-6-1:2007 Yes
EN 61000-6-3:2007 Yes

Package contents

Instrument WiFiScope WS5
Oscilloscope probes 2 x Oscilloscope Probe 1:1-1:10 - HP-3250I
Accessories Handyscope / WiFiScope power supply
USB3 cable, 1.5 m long
network cable, 3 m long
Software for Windows 10, via website
Drivers for Windows 10, via website
Software Development Kit for Windows 10 and Linux, via website
Manuals instrument manual and software user's manuals
color printed and digital, via website